Safety Data Sheets / Sub-X Mounting Medium
Safety Data Sheet
Sub-X Mounting Medium
1. Identification
Product Identifiers
- Product Name
- Sub-X Mounting Medium - DISCONTINUED
- Other Names
- Not available
- Product Number(s)
- 13519, EMS13519
- CAS Number
- Not available
Recommended use of the chemical and restriction on use
Laboratory chemicals.
Company Details
ProSciTech Pty Ltd
11 Carlton Street
KIRWAN QLD 4817
Australia
(07) 4773 9444
pst@proscitech.com
proscitech.com.au
11 Carlton Street
KIRWAN QLD 4817
Australia
(07) 4773 9444
pst@proscitech.com
proscitech.com.au
Emergency Contact Details
ProSciTech Pty Ltd
11 Carlton Street
KIRWAN QLD 4817
Australia
(07) 4773 9444
pst@proscitech.com
proscitech.com.au
11 Carlton Street
KIRWAN QLD 4817
Australia
(07) 4773 9444
pst@proscitech.com
proscitech.com.au
2. Hazards Identification
Classification of the substance or mixture
- GHS02 Flame
- Flammable liquids 2 H225 Highly flammable liquid and vapour.
- GHS08 Health hazard
- Specific Target Organ Toxicity - Repeated Exposure 2 H373 May cause damage to organs through prolonged or repeated exposure.
- Aspiration Hazard 1 H304 May be fatal if swallowed and enters airways.
- GHS07
- Skin Irritation 2 H315 Causes skin irritation.
- Specific Target Organ Toxicity - Single Exposure 3 H336 May cause drowsiness or dizziness.
Label Elements



- Signal Words
- None
- Hazard Statement(s)
- Hazard-determining components of labelling: toluene
- Highly flammable liquid and vapour.
- Causes skin irritation.
- May cause drowsiness or dizziness.
- May cause damage to organs through prolonged or repeated exposure.
- May be fatal if swallowed and enters airways.
- Precautionary Statement(s)
- Keep away from heat/sparks/open flames/hot surfaces. - No smoking.
- Ground/bond container and receiving equipment.
- Use explosion-proof electrical/ventilating/lighting/equipment.
- Use only non-sparking tools.
- Take precautionary measures against static discharge.
- Do not breathe dust/fume/gas/mist/vapours/spray.
- Wash thoroughly after handling.
- Use only outdoors or in a well-ventilated area.
- Wear protective gloves/protective clothing/eye protection/face protection.
Primary route(s) of entry
Not available.
Human Health
- Inhalation
- Remove person to fresh air and keep comfortable for breathing. Call a poison centre/doctor if you feel unwell.
- Ingestion
- Immediately call a poison centre/doctor. Do NOT induce vomiting.
- Eyes
- Not available.
- Skin
- (or hair) Take off immediately all contaminated clothing. Rinse skin with water/shower. Take off contaminated clothing and wash it before reuse. If skin irritation occurs: Get medical advice/attention.
Environment
- In case of fire: Use CO₂, powder or water spray to extinguish.
- Store in a well-ventilated place. Keep container tightly closed.
- Store in a well-ventilated place. Keep cool.
- Store locked up.
- Dispose of contents/container in accordance with local/regional/national/international regulations.
3. Composition / Information on Ingredients
| Name | CAS No. | Content (w/w) | Classification |
|---|---|---|---|
| toluene | 108-88-3 | >50-≤100% | Not Available |
4. First Aid Measures
- Ingestion
- If symptoms persist consult doctor.
- Inhalation
- In case of unconsciousness place patient stably in side position for transportation.
- Skin Contact
- Immediately wash with water and soap and rinse thoroughly.
- Eye Contact
- Rinse opened eye for several minutes under running water.
- Other Information
- Symptoms of poisoning may even occur after several hours; therefore medical observation for at least 48 hours after the accident.
5. Firefighting Measures
Suitable extinguishing equipment
- Fire
- CO₂, sand, extinguishing powder. Do not use water.
- HAZCHEM
- For safety reasons unsuitable extinguishing agents: Water with full jet.
Special protective equipment and precautions for fire fighters
No special measures required.
6. Accidental Release Measures
- Personal precautions, protective equipment and emergency procedures
- Wear protective equipment. Keep unprotected persons away.
- Environmental precautions
- Do not allow to enter sewers/surface or ground water.
- Methods and materials for containment and clean up
- Absorb with liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust).
- Dispose contaminated material as waste according to item 13.
- Ensure adequate ventilation.
- Do not flush with water or aqueous cleansing agents.
7. Handling and Storage
- Precautions for safe handling
- Ensure good ventilation/exhaustion at the workplace.
- Prevent formation of aerosols.
- Keep ignition sources away - Do not smoke.
- Protect from heat.
- Protect against electrostatic charges.
- Conditions for safe storage
- Store in a cool location.
- Keep receptacle tightly sealed.
- Store in cool, dry conditions in well sealed receptacles.
- Protect from heat and direct sunlight.
8. Exposure Controls / Personal Protection
Exposure Standards
| Material | TWA ppm | TWA mg/m³ | STEL ppm | STEL mg/m³ |
|---|---|---|---|---|
| 108-88-3 toluene | - | REL 375 mg/m³ | REL 150ppm | REL 560 mg/m³ |
- Engineering controls
- Keep away from foodstuffs, beverages and feed.
- Immediately remove all soiled and contaminated clothing.
- Wash hands before breaks and at the end of work.
- Avoid contact with the skin.
- Avoid contact with the eyes and skin.
Personal protective equipment
- Eye and face protection
- Tightly sealed goggles
- Skin protection
- Protective gloves. The glove material has to be impermeable and resistant to the product/the substance/the preparation. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.
- Body protection
- Protective clothing
- Respiratory protection
- In case of brief exposure or low pollution use respiratory filter device. In case of intensive or longer exposure use respiratory protective device that is independent of circulating air.
9. Physical and Chemical Properties
General information
- Appearance
- Colourless liquid
- Odour
- Mild
- pH
- Not determined
- Vapour Pressure
- 47 hPa
- Density
- 0.938g/cm³
- Boiling Point
- Undetermined
- Melting Point
- Undetermined
- Solubility
- Not miscible or difficult to mix.
- Specific Gravity of Density
- Not available.
- Flash Point
- 11.7°C
- Flammable (Explosive) Limits
- Lower: 1.2 Vol%
- Upper: 12.5 Vol%
- Ignition Temperature
- Not available.
- Formula
- Not available.
10. Stability and Reactivity
- Reactivity
- No further relevant information available.
- Chemical stability
- No decomposition if used according to specifications.
- Possibility of hazardous reactions
- No dangerous reactions known.
- Conditions to avoid
- No further relevant information available.
- Incompatible materials
- No further relevant information available.
11. Toxicological Information
- Acute effects
- Not available.
- Eye contact
- No irritating effect.
- Skin contact
- Irritant to skin and mucous membranes.
- Ingestion
- Not available.
- Inhalation
- No sensitising effects known.
- Toxicity and irritation
- Irritant
- Carcinogenic categories: IARC (international Agency for Research on Cancer) 108-83-3 toluene 3
12. Ecological Information
- Ecotoxicity
- No further relevant information available.
- Persistence and degradability
- No further relevant information available.
- Bioaccumulative potential
- No further relevant information available.
- Other adverse effects
- Water hazard class 3: extremely hazardous for water.
- Do not allow product to reach ground water, water course or sewage system, even in small quantities.
- Danger to drinking water if even extremely small quantities leak into the ground.
13. Disposal Considerations
General information
- Must not be disposed of together with household garbage. Do not allow product to reach sewage system.
- Disposal must be made according to official regulations.
14. Transport Information
ADG label required

- HAZCHEM
- For safety reasons unsuitable extinguishing agents: Water with full jet.
- UN Number
- UN1294
- Proper shipping name
- 1294 TOLUENE
- Transport hazard class
- class 3 Flammable liquids
- Packing group
- II
- Environmental hazard
- Not applicable.
- Special precautions for users
- Warning: Flammable liquids.
- Hazard identification number (Kemler code): 33
- EMS Number: F-E,S-D
- Stowage Category: B
- Additional information
- DOT
- Quantity limitations:
- On passenger aircraft/rail: 5L
- On cargo aircraft only: 60L
- ADR
- Excepted quantities (EQ) Code: E2
- Maximum net quantity per inner packaging: 30mL
- maximum net quantity per outer packaging: 500mL
- IMDG
- Limited quantities (LQ) 1L
- Excepted quantities (EQ) Code: E2
- Maximum net quantity per inner packaging: 30mL
- Maximum net quantity per outer packaging: 500ml
15. Regulatory Information
- Poisons Schedule Number
- Not available
- Other Information
- A Chemical Safety Assessment has not been carried out.
16. Other Information
- SDS preparation date
- 2 March 2026
- Comments
- This information is based on our present knowledge. However, this shall not constitute a guarantee for any specific product features and shall not establish a legally valid contractual relationship.