Safety Data Sheets / Mobil DTE Vacuum Pump Oil, Medium
Safety Data Sheet
Mobil DTE Vacuum Pump Oil, Medium
1. Identification
Product Identifiers
- Product Name
- Mobil DTE Vacuum Pump Oil, Medium
- Other Names
- DTE Oil Medium
- Product Number(s)
- M007
- CAS Number
- ?
Recommended use of the chemical and restriction on use
Laboratory use. Rotary vane vacuum pump oil; Turbine oil.
Company Details
ProSciTech Pty Ltd
11 Carlton Street
KIRWAN QLD 4817
Australia
(07) 4773 9444
pst@proscitech.com
proscitech.com.au
11 Carlton Street
KIRWAN QLD 4817
Australia
(07) 4773 9444
pst@proscitech.com
proscitech.com.au
Emergency Contact Details
ProSciTech Pty Ltd
11 Carlton Street
KIRWAN QLD 4817
Australia
(07) 4773 9444
pst@proscitech.com
proscitech.com.au
11 Carlton Street
KIRWAN QLD 4817
Australia
(07) 4773 9444
pst@proscitech.com
proscitech.com.au
2. Hazards Identification
Classification of the substance or mixture
Not classified as hazardous according to criteria of NOHSC.
Label Elements
- Signal Words
- Danger
- Hazard Statement(s)
- NON-HAZARDOUS SUBSTANCE. NON-DANGEROUS GOODS.
- Precautionary Statement(s)
- Not applicable.
Primary route(s) of entry
Not available.
Human Health
- Inhalation
- Not available.
- Ingestion
- Not available.
- Eyes
- Not available.
- Skin
- Not available.
Environment
No further relevant information available.
3. Composition / Information on Ingredients
No information provided.
4. First Aid Measures
- Ingestion
- First aid is normally not required. Seek medical attention if discomfort occurs.
- Inhalation
- Remove from further exposure. For those providing assistance, avoid exposure to yourself or others. Use adequate respiratory protection. If respiratory irritation, dizziness, nausea, or unconsciousness occurs, seek immediate medical assistance. If breathing has stopped, assist ventilation with a mechanical device or use mouth-to-mouth resuscitation.
- Skin Contact
- Wash contact areas with soap and water. If product is injected into or under the skin, or into any part of the body, regardless of the appearance of the wound or its size, the individual should be evaluated immediately by a physician as a surgical emergency. Even though initial symptoms from high pressure injection may be minimal or absent, early surgical treatment within the first few hours may significantly reduce the ultimate extent of injury.
- Eye Contact
- Flush thoroughly with water. If irritation occurs, get medical assistance.
- Other Information
- No further relevant information available.
5. Firefighting Measures
Suitable extinguishing equipment
- Fire
- Use water fog, foam, dry chemical or carbon dioxide (CO₂) to extinguish flames. DO NOT USE straight streams of water.
- Large Fire
- Use water fog, foam, dry chemical or carbon dioxide (CO₂) to extinguish flames. DO NOT USE straight streams of water.
- HAZCHEM
- Not available.
Special protective equipment and precautions for fire fighters
No special measures required.
6. Accidental Release Measures
- Personal precautions, protective equipment and emergency procedures
- Avoid contact with spilled material. See Section 5 for firo fighting information. See the Hazard Identification Section for Significant Hazards. See Section 4 for First Aid Advice. See Section 8 for advice on the minimum requirements for personal protective equipment. Additional protective measures may be necessary, depending on the specific circumstances and/or the export judgment of the emergency responders. For emergency responders: Respiratory protection: respiratory protection will be necessary only In special cases, e.g., formation of mists. Half-face or full-face respirator with filter(s) for dust/organic vapour or Self Contained Breathing Apparatus (SCBA) can be used depending on the size of spill and potential level of exposure. If the exposure cannot be completely characterised or an oxygen deficient atmosphere Is possible or anticipated, SCBA Is recommended. Work gloves that are resistant to hydrocarbons are recommended. Gloves made of polyvinyl acetate (PVA) arc not water-resistant and are not suitable for emergency use. Chemical goggles are recommended if splashes or contact with eyes is possible. Small spills: normal antistatic work clothes are usually adequate. Large spills: full body suit of chemical resistant, antistatic material is recommended.
- Environmental precautions
- Large Spills: Dyke far ahead of liquid spill for later recovery and disposal. Prevent entry into waterways, sewers, basements or confined areas.
- Methods and materials for containment and clean up
- Notify relevant authorities in accordance with all applicable regulations.Land Spill: Stop leak if you can do so without risk. Recover by pumping or with suitable absorbent.
- Water Spill: Stop leak if you can do so without risk. Confine the spill immediately with booms. Warn other shipping. Remove from the surface by skimming or with suitable absorbents. Seek the advice of a specialist before using dispersants. Water spill and land spill recommendations are based on the most likely spill scenario for this material; however, geographic conditions, wind, temperature, (and in the case of a water spill) wave and current direction and speed may greatly influence the appropriate action to be taken. For this reason, local experts should be consulted. Note: Local regulations may prescribe or limit action to be taken.
7. Handling and Storage
- Precautions for safe handling
- Prevent small spills and leakage to avoid slip hazard. This material is a static accumulator.
- Material can accumulate static charges which may cause an electrical spark (ignition source). When the material is handled in bulk, an electrical spark could ignite any flammable vapours from liquids or residues that may be present (e.g., during switch-loading operations). Use proper bonding and/or ground procedures. However, bonding and grounds may not eliminate the hazard from static accumulation. Consult local applicable standards for guidance.
- Conditions for safe storage
- The container choice, for example storage vessel, may effect static accumulation and dissipation In open or unlabelled containers. Keep away from incompatible materials.
- Do not store in open or unlabelled containers.
8. Exposure Controls / Personal Protection
Exposure Standards
- Engineering controls
- The level of protection and types of controls necessary will vary depending upon potential exposure conditions.Control measures to consider: No special requirements under ordinary conditions of use and with adequate ventilation.
Personal protective equipment
- Eye and face protection
- If contact is likely, safety glasses with side shields are recommended.
- Skin protection
- Any specific glove information provided is based on published literature and glove manufacturer data. Glove suitability and breakthrough time will differ depending on the specific use conditions. Contact the glove manufacturer for specific advice on glove selection and breakthrough times for your use conditions. Inspect and replace worn or damaged gloves. The types of gloves to be considered for this material include: Nitrile, Viton.
- No protection is ordinarily required under normal conditions of use.Any specific clothing information provided is based on published literature or manufacturer data. The types of clothing to be considered for this material include:
- No skin protection is ordinarily required under normal conditions of use. In accordance with good industrial hygiene practices, precautions should be taken to avoid skin contact.
- Body protection
- Always observe good personal hygiene measures, such as washing after handling the material and before eating, drinking, and/or smoking. Routinely wash work clothing and protective equipment to remove contaminants. Discard contaminated clothing and footwear that cannot be cleaned. Practice good housekeeping.Personal protective equipment selections vary based on potential exposure conditions such as applications, handling practices, concentration and ventilation. Information on the selection of protective equipment for use with this material, is based upon intended, normal usage.
- Respiratory protection
- If engineering controls do not maintain airborne contaminant concentrations at a level which is adequate to protect worker health, an approved respirator may be appropriate. Respirator selection, use, and maintenance must be in accordance with regulatory requirements, if applicable.Types of respirators to be considered for this material include:
- Particulate: No special requirements under ordinary conditions of use and with adequate ventilation.
- For high airborne concentrations, use an approved supplied-air respirator, operated in positive pressure mode. Supplied air respirators with an escape bottle may be appropriate when oxygen levels are inadequate, gas/vapour warning properties are poor, or if air purifying filter capacity/rating may be exceeded.
9. Physical and Chemical Properties
General information
- Appearance
- Amber liquid.
- Odour
- Characteristic.
- pH
- Not available.
- Vapour Pressure
- < 0.013 kPa (0.1 mm Hg) at 20°C
- Density
- (Air = 1): > 2 at 101 kPa
- Boiling Point
- > 316°C
- Melting Point
- Not available.
- Solubility
- Negligible solubility in water.
- Specific Gravity of Density
- Relative density at 15°C: 0.87
- Flash Point
- >200°C.
- Flammable (Explosive) Limits
- LEL: 0.9 UEL: 7.0
- Ignition Temperature
- Not available.
- Formula
- Not available.
10. Stability and Reactivity
- Reactivity
- No further relevant information available.
- Chemical stability
- Stable under normal conditions of use. Material does not decompose at ambient temperatures.
- Possibility of hazardous reactions
- Will not occur.
- Conditions to avoid
- Excessive heat. High energy sources of ignition and incompatible materials.
- Incompatible materials
- Strong oxidisers.
11. Toxicological Information
- Acute effects
- No further relevant information available.
- Eye contact
- Excessive exposure may result in eye irritation.
- Irritation (Rabbit): Data available. May cause mild, short-lasting discomfort to eyes. Based on test data for structurally similar materials
- Skin contact
- Excessive exposure may result in skin irritation; high-pressure injection under skin may cause serious damage.Toxicity (Rabbit): LD50 > 5000 mg/kg
- Minimally Toxic. Based on test data for structurally similar materials.
- Irritation (Rabbit): Data available. Negligible irritation to skin at ambient temperatures. Based on test data for structurally similar materials.
- Ingestion
- Low order of toxicity ? effects unknown.Toxicity (Rat): LD50 > 5000 mg/kg
- Minimally Toxic. Based on test data for structurally similar materials
- Inhalation
- Excessive exposure may result in respiratory irritation.
- Toxicity (Rat): LC50 > 5000 mg/m³
- Minimally Toxic. Based on test data for structurally similar materials.
- Irritation: No end point data. Negligible hazard at ambient/normal handling temperatures. Based on assessment of the components.
- Toxicity and irritation
- No further relevant information available.
12. Ecological Information
- Ecotoxicity
- Not expected to be harmful to aquatic organisms.
- Persistence and degradability
- Base oil component ? Expected to be inherently biodegradable
- Bioaccumulative potential
- Has the potential to bioaccumulate, however metabolism or physical properties may reduce the bioconcentration or limit bioavailability.
- Other adverse effects
- Base oil component ? Low solubility and floats and is expected to migrate from water to the land. Expected to partition to sediment and wastewater solids.
13. Disposal Considerations
General information
- Disposal recommendations based on material as supplied. Disposal must be in accordance with current applicable laws and regulations, and material characteristics at time of disposal. Product is suitable for burning in an enclosed controlled burner for fuel value or disposal by supervised incineration at very high temperatures to prevent formation of undesirable combustion products.
- Special Precautions: Empty Container Warning (where applicable): Empty containers may contain residue and can be dangerous. Do not attempt to refill or clean containers without proper instructions. Empty drums should be completely drained and safely stored until appropriately reconditioned or disposed. Empty containers should be taken for recycling, recovery, or disposal through suitably qualified or licensed contractor and in accordance with governmental regulations. DO NOT PRESSURISE, CUT, WELD, BRAZE, SOLDER, DRILL, GRIND, OR EXPOSE SUCH CONTAINERS TO HEAT, FLAME, SPARKS, STATIC ELECTRICITY, OR OTHER SOURCES OF IGNITION. THEY MAY EXPLODE AND CAUSE INJURY OR DEATH.
14. Transport Information
ADG label required
- HAZCHEM
- Not available.
- UN Number
- None.
- Proper shipping name
- Not regulated.
- Transport hazard class
- 0
- Packing group
- None.
- Environmental hazard
- Not regulated.
- Special precautions for users
- Not regulated.
- Additional information
- Not regulated.
15. Regulatory Information
- Poisons Schedule Number
- Not regulated.
- Other Information
- No further information available.
16. Other Information
- SDS preparation date
- 25 February 2026
- Comments
- This information is based on our present knowledge. However, this shall not constitute a guarantee for any specific product features and shall not establish a legally valid contractual relationship.
- References
- List of Publications referenced when creating this MSDS;
- Hazardous Substances Information System Consolidated Lists: Safe Work Australia.
- APPROVED CRITERIA FOR CLASSIFYING HAZARDOUS SUBSTANCES [NOHSC:1008(2004)] 3rd Edition: National Occupational Health and Safety Commission.
- Dangerous Goods ? Initial Emergency Response Guide (SAA/SNZ HB76:1997).
- IATA Dangerous Goods Regulations.
- Adopted National Exposure Standards for Atmospheric Contaminants in the Occupational Environment [NOHSC:1003(1995)].
- Australia Standard for the Uniform Scheduling of Drugs and Poisons [SUSPD] (Australian Government Department of Health and Ageing).