Safety Data Sheets / Conductive Gold Paste Extender
Safety Data Sheet
Conductive Gold Paste Extender
1. Identification
Product Identifiers
- Product Name
- Conductive Gold Paste Extender
- Other Names
- Not available
- Product Number(s)
- 12643, EMS12643
- CAS Number
- 107-98-2
Recommended use of the chemical and restriction on use
Laboratory chemicals.
Company Details
ProSciTech Pty Ltd
11 Carlton Street
KIRWAN QLD 4817
Australia
(07) 4773 9444
pst@proscitech.com
proscitech.com.au
11 Carlton Street
KIRWAN QLD 4817
Australia
(07) 4773 9444
pst@proscitech.com
proscitech.com.au
Emergency Contact Details
ProSciTech Pty Ltd
11 Carlton Street
KIRWAN QLD 4817
Australia
(07) 4773 9444
pst@proscitech.com
proscitech.com.au
11 Carlton Street
KIRWAN QLD 4817
Australia
(07) 4773 9444
pst@proscitech.com
proscitech.com.au
2. Hazards Identification
Classification of the substance or mixture
- GHS02 Flame
- Flam. Liq. 3 H226 Flammable liquid and vapour.
- GHS06 Skull and crossbones.
- Acute Tox. 3 H331 Toxic if inhaled.
- GHS08 Health hazard
- Repr. 1B H360 May damage fertility or the unborn child.
- GHS07
- Eye Irrit. 2A H319 Causes serious eye irritation.
- STOT SE 3 H336 May cause drowsiness or dizziness.
Label Elements




- Signal Words
- None
- Hazard Statement(s)
- Hazard-determining components of labelling:
- 1-methoxy-2-propanol
- 2-methoxypropanol
- Flammable liquid and vapour.
- Toxic if inhaled.
- Causes serious eye irritation.
- May damage fertility or the unborn child.
- May cause drowsiness or dizziness.
- Precautionary Statement(s)
- Obtain special instructions before use.
- Do not handle until all safety precautions have been read and understood.
- Keep away from heat/sparks/open flames/hot surfaces. No smoking.
- Ground/bond container and receiving equipment.
- Use explosion-proof electrical/ventilating/lighting equipment.
- Use only non-sparking tools.
- Take precautionary measures against static discharge.
- Avoid breathing dust/fume/gas/mist/vapours/spray.
- Wash thoroughly after handling.
- Use only outdoors or in a well-ventilated area.
- Wear protective gloves/protective clothing/eye protection/face protection.
Primary route(s) of entry
Not available.
Human Health
- Inhalation
- Remove victim to fresh air and keep at rest in a position comfortable for breathing.
- Ingestion
- If exposed or concerned: Get medical advice/attention.
- Eyes
- Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. If eye irritation persists: Get medical advice/attention.
- Skin
- (or hair) Remove/Take off immediately all contaminated clothing. Rinse skin with water/shower.
Environment
- In case of fire: Use CO₂, powder or water spray for extinction.
- Store in a well-ventilated place. Keep container tightly closed.
- Store in a well-ventilated place. Keep cool.
- Store locked up.
- Dispose of contents/container in accordance with local/regional/national/international regulations.
3. Composition / Information on Ingredients
| Name | CAS No. | Content (w/w) | Classification |
|---|---|---|---|
| 2-methoxypropanol | 1589-47-5 | ≤2.5% | Not Available |
4. First Aid Measures
- Ingestion
- If symptoms persist consult doctor.
- Inhalation
- Supply fresh air or oxygen; call for a doctor.
- In case of unconsciousness place patient stably in side position for transportation.
- Skin Contact
- Immediately wash with water and soap and rinse thoroughly.
- Eye Contact
- Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor.
- Other Information
- Immediately remove any clothing soiled by the product.
- Remove breathing equipment only after contaminated clothing have been completely removed.
- In case of irregular breathing or respiratory arrest provide artificial respiration.
5. Firefighting Measures
Suitable extinguishing equipment
- Fire
- CO, powder or water spray. Fight larger fires with water spray or alcohol resistant foam.
- HAZCHEM
- No further relevant information available.
Special protective equipment and precautions for fire fighters
Mouth respiratory protective device.
6. Accidental Release Measures
- Personal precautions, protective equipment and emergency procedures
- Wear protective equipment. Keep unprotected persons away.
- Environmental precautions
- Dilute with plenty of water.
- Do not allow to enter sewers/surface or ground water.
- Methods and materials for containment and clean up
- Absorb with liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust).
- Dispose contaminated material as waste according to item 13.
- Ensure adequate ventilation.
7. Handling and Storage
- Precautions for safe handling
- Ensure good ventilation/exhaustion at the workplace.
- Open and handle receptacle with care.
- Prevent formation of aerosols.
- Keep ignition sources away - Do not smoke.
- Protect from heat.
- Protect against electrostatic charges.
- Keep respiratory protective device available.
- Conditions for safe storage
- Keep container tightly sealed.
- Protect from heat and direct sunlight.
8. Exposure Controls / Personal Protection
Exposure Standards
| Material | TWA ppm | TWA mg/m³ | STEL ppm | STEL mg/m³ |
|---|---|---|---|---|
| 107-98-2 1-methoxy-2-propanol | 100ppm | 369mg/m³ | 150ppm | 553mg/m³ |
- Engineering controls
- Keep away from foodstuffs, beverages and feed.
- Immediately remove all soiled and contaminated clothing.
- Wash hands before breaks and at the end of work.
- Store protective clothing separately.
- Avoid contact with the eyes and skin.
Personal protective equipment
- Eye and face protection
- Tightly sealed goggles.
- Skin protection
- Wear protective gloves. The glove material has to be impermeable and resistant to the product/the substance/the preparation. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.
- Body protection
- Wear protective clothing.
- Respiratory protection
- In case of brief exposure or low pollution use respiratory filter device. In case of intensive or longer exposure use self-contained respiratory protective device.
9. Physical and Chemical Properties
General information
- Appearance
- Clear liquid
- Odour
- Characteristic
- pH
- 4-7
- Vapour Pressure
- 12hPa
- Density
- 3.11g/cm³
- Boiling Point
- 120.3°C
- Melting Point
- -96.7°C
- Solubility
- Fully miscible
- Specific Gravity of Density
- Not available
- Flash Point
- 35°C
- Flammable (Explosive) Limits
- Lower: 2.3 Vol%
- Upper: -20 Vol%
- Ignition Temperature
- 270°C
- Formula
- Not available
10. Stability and Reactivity
- Reactivity
- No further relevant information available.
- Chemical stability
- No decomposition if used according to specifications.
- Possibility of hazardous reactions
- No dangerous reactions known.
- Conditions to avoid
- No further relevant information available.
- Incompatible materials
- No further relevant information available.
11. Toxicological Information
- Acute effects
- 107-98-2 1-methoxy-2-propanol
- Oral LD50 5660 mg/kg (rat)
- Dermal LD50 13000 mg/kg (rabbit)
- Inhalative LC50/4 h 6 mg/l (rat)
- Eye contact
- Irritating effects.
- Skin contact
- Irritant to skin and mucous membranes.
- Ingestion
- Not available.
- Inhalation
- No sensitising effects known.
- Toxicity and irritation
- Not available.
12. Ecological Information
- Ecotoxicity
- No further relevant information available.
- Persistence and degradability
- No further relevant information available.
- Bioaccumulative potential
- No further relevant information available.
- Other adverse effects
- Water hazard class1: slightly hazardous for water.
- Do not allow undiluted product or large quantities of it to reach ground water, water course or sewage system.
13. Disposal Considerations
General information
- Must not be disposed together with household garbage. Do not allow product to reach sewage system.
- Disposal must be made according to official regulations.
- Recommended cleansing agents: Water, if necessary together with cleansing agents.
14. Transport Information
ADG label required

- HAZCHEM
- No further relevant information available.
- UN Number
- UN3092
- Proper shipping name
- 3091 1-METHOXY-2-PROPANOL
- Transport hazard class
- Class 3 Flammable liquids.
- Packing group
- III
- Environmental hazard
- Not applicable
- Special precautions for users
- Warning: Flammable liquids.
- Hazard identification number (Kemler code): 30
- EMS Number: F-E,S-D
- Stowage Category: A
- Additional information
- Limited quantities (LQ) 5L
- Excepted quantities (EQ) Code: E1
- Maximum net quantity per inner packaging: 30mL
- Maximum net quantity per outer packaging: 1000mL
- Transport category: 3
- Tunnel restriction code: D/E
15. Regulatory Information
- Poisons Schedule Number
- None of the ingredients is listed.
- Other Information
- A Chemical Safety Assessment has not been carried out.
16. Other Information
- SDS preparation date
- 27 November 2024
- Comments
- This information is based on our present knowledge. However, this shall not constitute a guarantee for any specific product features and shall not establish a legally valid contractual relationship.